CNFC-ET PEM Electrolyzer Stack Test Station 0-500kW High Precision Flow Control Wide Back Pressure Range
| Product Type: | PEM Electrolyzer Stack Test Station / PEM Electrolyzer Test Bench | Product Model: | CNFC-ET |
| Testing Power Range: | 0-500kW | Hydrogen Flow Range: | 10-3000 SLPM |
| Oxygen Flow Range: | 5-1500 SLPM | Flow Measurement Accuracy: | Within ±0.25%FS |
| Back Pressure Control Range: | 100-5000kPa | Temperature Control Range: | Room Temperature +10 To 90 Degrees C |
| Voltage Inspection Accuracy: | Less Than 1mV | Safety System: | Independent Safety PLC, Linkable With Laboratory Safety Management System |
| Customization: | Power Class And Configuration Customizable | ||
| High Light: | PEM Electrolyzer Stack Test Station,CNFC-ET 0-500kW Testing Platform,High Precision Flow Control 0.25%FS |
||
CNFC-ET PEM Electrolyzer Stack Test Station
Testing Power 0-500kW | High Precision Flow Control within 0.25%FS | Wide Back Pressure Range 5MPa | Independent Safety PLC
Quick Detail
- High precision test platform developed for the R&D, testing and end-of-line inspection of proton exchange membrane (PEM) electrolyzer stacks
- Testing power coverage: 0-500kW, meeting the testing needs of electrolyzers of different power classes
- Modular design with the advantages of complete functions, high precision, fast response, convenient control and stable performance
- Flow measurement accuracy: within ±0.25%FS
- Hydrogen flow range: 10-3000 SLPM; oxygen flow range: 5-1500 SLPM
- Nitrogen flow control range: 10-1000 SLPM
- Gas pressure measurement range: 1-5MPa; back pressure control range: 100-5000 kPa
- Temperature control range: room temperature +10°C to 90°C
- Integrated independent safety PLC system, linkable with the laboratory safety management system to ensure laboratory hydrogen safety
- Integrated with multiple national and enterprise standard test conditions, enabling automated experiments with one-click test report generation after testing
- Cost about 30% lower than mainstream comparable equipment on the market
Description
The electrolyzer test station is professional testing equipment developed for the product development and application needs of the PEM electrolyzer testing field. The equipment can meet the needs of electrolyzers at different stages such as R&D, test calibration and end-of-line inspection, featuring complete power coverage, high precision, fast response, convenient control and stable performance.
The CNFC-ET electrolyzer test station can test, analyze and verify technical indicators such as the performance, efficiency, durability and electrochemical characteristics of the PEM electrolyzer membrane electrode assembly, supporting the product development and scientific research of PEM electrolyzers.
Core Test Capability
- Water Supply System: Temperature control range room temperature +10°C to 90°C (accuracy within ±0.5°C), heating rate ≥3°C/min, flow range 50-500 LPM (accuracy within ±1%FS), conductivity range 0.05-5 µS/cm
- Gas System: Hydrogen flow 10-3000 SLPM, oxygen flow 5-1500 SLPM, nitrogen flow control 10-1000 SLPM (accuracy within ±1%FS), gas pressure measurement range 1-5MPa (accuracy within ±0.1%), back pressure control range 100-5000kPa
- DC Power Supply: Power 0-500kW, voltage range 0-400V (accuracy within 0.1%FS+5dgt), current range 0-4000A (accuracy within 0.1%FS+5dgt), response time within 5ms
- Voltage Inspection: Single cell inspection channels 100, single cell voltage measurement range -5V to +5V, voltage measurement accuracy less than 1mV, sampling period less than 100ms
- Test Conditions: Polarization curve test, sensitivity test, cell consistency test, hydrogen-in-oxygen / oxygen-in-hydrogen test, power/efficiency test, durability test, pure water conductivity test
- Safety Design: Independent safety PLC system, linkable with the laboratory safety management system to ensure laboratory hydrogen safety; equipped with hydrogen leakage alarm, online insulation detection, emergency stop and other functions to fully guarantee safe and reliable testing
Specifications
| Item | Specification |
|---|---|
| System | |
| Power | 0-500kW |
| Voltage Range | 0-400V |
| Current Range | 0-4000A |
| Gas Output Channels | Hydrogen, Oxygen |
| Working Mode | Programmable automatic operation, also with manual control |
| Water Supply System | |
| Temperature Control Range | Room temperature +10°C to 90°C |
| Temperature Control Accuracy | Within ±0.5°C |
| Heating Rate | ≥3°C/min |
| Flow Range | 50-500 LPM |
| Flow Accuracy | Within ±1%FS |
| Conductivity Range | 0.05-5 µS/cm |
| Gas System | |
| Flow Measurement Accuracy | Within ±0.25%FS |
| Hydrogen Flow Range | 10-3000 SLPM |
| Oxygen Flow Range | 5-1500 SLPM |
| Nitrogen Flow Control Range | 10-1000 SLPM |
| Nitrogen Flow Control Accuracy | Within ±1%FS |
| Gas Pressure Measurement Range | 1-5MPa |
| Gas Pressure Measurement Accuracy | Within ±0.1% |
| Back Pressure Control Range | 100-5000kPa |
| Back Pressure Control Accuracy | Within ±3kPa (100-1000 kPa); within ±5kPa (1001-5000 kPa) |
| DC Power Supply | |
| Power | 0-500kW |
| Voltage Range | 0-400V |
| Voltage Accuracy | Within 0.1%FS+5dgt |
| Response Time | Within 5ms |
| Current Range | 0-4000A |
| Current Accuracy | Within 0.1%FS+5dgt |
| Voltage Inspection | |
| Single Cell Inspection Channels | 100 |
| Single Cell Voltage Measurement | -5V to +5V |
| Voltage Measurement Accuracy | Less than 1mV |
| Sampling Period | Less than 100ms |
Applications
This product is widely used in the R&D, testing and end-of-line inspection of PEM electrolyzers, including:
- PEM electrolyzer R&D: polarization curve test, sensitivity test, durability test
- Electrolyzer end-of-line inspection: performance verification and calibration before leaving the factory
- Electrolyzer performance evaluation: power/efficiency test, cell consistency test
- Electrolyzer safety test: hydrogen-in-oxygen / oxygen-in-hydrogen test, pure water conductivity test
- Key parameter detection of the hydrogen production system: electrolyzer hydrogen/oxygen side outlet pressure, voltage/current/power, cell voltage, hydrogen production pressure, hydrogen flow, oxygen-in-hydrogen concentration, oxygen flow, hydrogen-in-oxygen concentration, etc.
- Research institutes and university laboratories: water electrolysis hydrogen production teaching and research experiment platform
Company Advantages
Shanghai Yibaijia Hydrogen Energy Technology Co., Ltd., as a professional hydrogen energy component supply platform, distributes the CNFC-ET series PEM electrolyzer test station. With more than 10 years of experience in the hydrogen energy industry, the Shanghai Yibaijia team can provide full-process technical support from product selection and system matching to installation and commissioning.
FAQ
Q1: Can samples be provided for testing?
Answer: Yes, we support sample orders for vehicle installation testing and performance verification, and also accept mixed-model sample orders.
Q2: What is the delivery cycle?
Answer: Sample orders are usually 30-45 working days; bulk orders (depending on order quantity) are generally 60-90 working days.
Q3: Is there a minimum order quantity (MOQ) limit?
Answer: There is no strict MOQ limit; 1 unit sample trial purchase is supported, and bulk orders enjoy better prices.
Q4: What electrolyzer power range does the CNFC-ET test station support?
Answer: The CNFC-ET test station covers a power range of 0-500kW, meeting the testing needs of PEM electrolyzers of different power classes. The specific power can be customized according to customer needs.
Q5: What is the flow measurement accuracy of the test station?
Answer: The flow measurement accuracy is within ±0.25%FS, using high-precision sensors to solve the difficulty of hydrogen flow that cannot be measured or measured inaccurately, verified through long-term operation in a hydrogen energy testing laboratory.
Q6: What types of test conditions does the test station support?
Answer: It supports polarization curve test, sensitivity test, cell consistency test, hydrogen-in-oxygen / oxygen-in-hydrogen test, power/efficiency test, durability test, pure water conductivity test, etc.
Q7: What is the gas pressure measurement range and accuracy of the test station?
Answer: The gas pressure measurement range is 1-5MPa with a measurement accuracy within ±0.1%. The back pressure control range is 100-5000kPa.
Q8: What are the safety measures of the test station?
Answer: The product has an independent safety PLC system, linkable with the laboratory safety management system to ensure laboratory hydrogen safety. It is equipped with hydrogen leakage alarm, online insulation detection, emergency stop and other functions.
Q9: What is the voltage inspection accuracy of the test station?
Answer: Single cell inspection channels 100, voltage measurement accuracy less than 1mV, sampling period less than 100ms.
Q10: How are product faults handled?
Answer: We implement a strict quality control system, with a factory defect rate below 0.2%. During the warranty period, small batches of defective products will be replaced with new ones in the next order; bulk quality problems will be negotiated for repair or replacement, ensuring customer rights.