Fuel Cell Tail Drain Tank 5L 304 Stainless Steel Integrated Muffler Optional Level Sensor

Basic Properties
Place of Origin: China
Brand Name: Shanghai Yibaijia
Certification: IATF16949
Model Number: Per customer requirements
Trading Properties
Minimum Order Quantity: Negotiable (10-piece sample trial order supported)
Price: Negotiable
Payment Terms: T/T,L/C,Western Union
Supply Ability: Negotiable according to customer requirements
Specifications
Product Type: Tail Drain Tank / Water Collection Tank Capacity: 5L
Material: 304 Stainless Steel Integrated Function: Muffler, Level Sensor (optional)
Applicable System Power: 5~15kW Typical Application: Fuel Cell Forklifts, Etc.
High Light:

Tail Drain Tank

,

5L Storage Capacity

,

Integrated Muffler

Product Description

Fuel Cell Dedicated Tail Drain Tank Adapting to 5~15kW Systems 5L Capacity Integrated Muffler 304 Stainless Steel Suitable for Forklifts Optional Level Sensor

Quick Detail:

  • Tail drain tank developed specifically for small proton exchange membrane fuel cell (PEMFC) systems
  • Applicable power range: 5~15kW (mainly used in fuel cell forklifts and other special vehicles)
  • Core function: collects and temporarily stores the liquid water discharged by the fuel cell system, and discharges it to a designated location in scenarios where it cannot be drained at any time
  • Capacity: 5L
  • Integrated muffler: reduces tail exhaust gas noise and improves vehicle NVH performance
  • Optional level sensor: outputs a signal when the level reaches the set height, prompting timely drainage
  • Material: 304 stainless steel (corrosion-resistant, high-temperature resistant, long life)
  • Application scenario: forklifts and other special vehicles that cannot drain at any time

Description:

In a fuel cell system, the water generated by the stack chemical reaction needs to be periodically discharged from the system. In the application scenarios of special vehicles such as forklifts, when the vehicle operates indoors such as in warehouses and workshops, it cannot discharge water to the ground at any time, so the water generated by the fuel cell system must be collected into a storage tank for temporary storage, and discharged in a centralized manner after the vehicle travels to a designated drainage area.

This tail drain tank has a capacity of 5L, meeting the water storage demand of small fuel cell systems (5~15kW) for a certain period under typical working conditions. The tank body uses 304 stainless steel material, with excellent corrosion resistance and structural strength, able to operate reliably over the long term in the complex temperature and humidity environment of the fuel cell system.

The product integrates a muffler function, effectively suppressing the exhaust noise while collecting the tail drain water. Aiming at the characteristics of the fuel cell tail exhaust noise (wide frequency band, high frequency), its muffler product insertion loss exceeds 20dB, with good noise reduction in the 1000~10000Hz frequency band; it uses a stainless steel straight-through pipe design with small exhaust back pressure and good corrosion resistance.

The product can be optionally equipped with a level sensor, installed inside the tank, to monitor the water level in real time. When the stored water reaches the set level, the sensor outputs a signal to the fuel cell system controller, prompting the operator to discharge the water to a designated location in time and preventing the tank from overflowing. The sensor type can be optionally float type.

Specifications:

Electrical / Optical Characteristics (Ta=25C +/-3C). See product specification image.

Fuel Cell Tail Drain Tank 5L 304 Stainless Steel Integrated Muffler Optional Level SensorApplications:

This product is widely used in small proton exchange membrane fuel cell (PEMFC) systems, specifically including:

  • Fuel cell forklifts (indoor operation scenarios such as warehouses and workshops, where drainage cannot be done at any time)
  • Fuel cell special vehicles (operation scenarios requiring centralized drainage in specific areas)
  • Small stationary fuel cell power stations
  • Fuel cell system test benches

Typical application scenario: when forklifts and other construction machinery operate in indoor scenarios such as warehouses and workshops, they cannot discharge the water generated by the fuel cell reaction to the ground at will. The system first collects the water into the tail drain tank for temporary storage, and discharges it in a centralized manner after the vehicle travels to a designated drainage area. The 5L capacity meets the water storage demand of small fuel cell systems for a certain period under typical working conditions.

Company Advantages:

Shanghai Yibaijia Hydrogen Energy Technology Co., Ltd., as a professional hydrogen energy parts supply platform, distributes tail drain tanks dedicated to fuel cells. This product uses 304 stainless steel, has a capacity of 5L, integrates a muffler function, and can be optionally equipped with a level sensor; it is mainly used in forklifts and other small fuel cell special vehicles. The Shanghai Yibaijia team has more than 10 years of hydrogen energy industry experience and can provide full-process technical support from product selection and system matching to installation.

FAQ

Q1: Can you provide samples for testing?
A: Yes, we support sample orders for vehicle installation testing and performance verification, and also accept mixed-model sample orders.

Q2: What is the delivery lead time?
A: Sample orders usually take 5-7 working days; bulk orders (depending on order quantity) generally take 15-30 working days.

Q3: Is there a minimum order quantity (MOQ) limit?
A: 10-piece sample trial orders are supported, and bulk order prices are more favorable.

Q4: Why does a fuel cell system need a tail drain tank?
A: In the application scenarios of special vehicles such as forklifts, when the vehicle operates indoors such as in warehouses and workshops, it cannot discharge water to the ground at any time. The role of the tail drain tank is to collect the water generated by the fuel cell system into a storage tank for temporary storage, and discharge it in a centralized manner after the vehicle travels to a designated drainage area.

Q5: What is the capacity of the tail drain tank?
A: The capacity is 5L, meeting the water storage demand of 5~15kW small fuel cell systems for a certain period under typical working conditions.

Q6: What material is the tail drain tank made of?
A: 304 stainless steel, with excellent corrosion resistance and structural strength, able to operate reliably over the long term in the complex temperature and humidity environment of the fuel cell system.

Q7: What functions are integrated into the tail drain tank?
A: The product integrates a muffler function, effectively suppressing the tail exhaust gas noise. It can also be optionally equipped with a level sensor to monitor the water level in real time and prompt timely drainage.

Q8: What role does the level sensor play?
A: When the stored water reaches the set level, the sensor outputs a signal to the fuel cell system controller, prompting the operator to discharge the water to a designated location in time and preventing the tank from overflowing.

Q9: What scenarios is the tail drain tank mainly used in?
A: Mainly used in fuel cell forklifts and other special vehicles, when drainage cannot be done at any time in indoor operation scenarios such as warehouses and workshops.

Q10: How to handle product failures?
A: We implement a strict quality control system, with an out-of-factory defect rate below 0.2%. During the warranty period, small batches of defective products will be replaced with new ones in the next order; batch quality problems will be negotiated for repair or replacement to ensure customer rights.